Различия

Здесь показаны различия между двумя версиями данной страницы.

Ссылка на это сравнение

Следующая версия
Предыдущая версия
sensors:t:bt_henry_guidotti_thomson [2015/10/09 08:37]
admin created
sensors:t:bt_henry_guidotti_thomson [2018/11/12 15:08] (текущий)
Строка 1: Строка 1:
-====== Bt: Henry, Guidotti, Thomson, for metapelites, 2005 ======+====== Bt: Henry, Guidotti, Thomson, 2005 ======
  
 The relationship between Ti-content, temperature,​ and Mg/(Mg + Fe) value was calibrated empirically using an extensive natural biotite data set (529 samples) from western Maine and south-central Massachusetts in combination with the petrogenetic grid of Spear et al. (1999). The relationship between Ti-content, temperature,​ and Mg/(Mg + Fe) value was calibrated empirically using an extensive natural biotite data set (529 samples) from western Maine and south-central Massachusetts in combination with the petrogenetic grid of Spear et al. (1999).
Строка 5: Строка 5:
 === Details === === Details ===
  
-^ Article | Darrell J. Henry, Charles V. Guidotti, Jennifer A. Thomson The Ti-saturation surface for low-to-medium pressure metapelitic biotites: Implications for geothermometry and Ti-substitution mechanisms American Mineralogist,​ Volume 90, pages 316–328, 2005 | +^ Article | <ref:henry2005|
-^ Reference | {{:sources:henry2005.pdf}} ​|+
 ^ Collibration | 529 samples form western Maine and south-central Massachusetts in combination with the petrogenetic grid of Spear et al. ,  XMg = 0.275–1.000,​ Ti = 0.04–0.60 apfu, and T = 480–800 °C. | ^ Collibration | 529 samples form western Maine and south-central Massachusetts in combination with the petrogenetic grid of Spear et al. ,  XMg = 0.275–1.000,​ Ti = 0.04–0.60 apfu, and T = 480–800 °C. |
-Presition ​| ± 24 °C |+Precision ​| ± 24 °C |
 ^ Ranges | 4 < P < 6  kbar,  480 °C < T < 800 °C | ^ Ranges | 4 < P < 6  kbar,  480 °C < T < 800 °C |
 ^ Renew sensors |  | ^ Renew sensors |  |
-^[[:ppy:mod_sensors#​t_bt_henry_guidotti_thomson|Calculate]] ^ ^+ 
 +<use:sensors.t.bt_henry_guidotti_thomson>​ 
 +<test:sensors.t.bt_henry_guidotti_thomson>​ 
 + 
 +<WRAP center round todo 60%> 
 +Для улучшения этой статьи следует:​ 
 +  * Добавить подробное описание 
 +  * Добавить тест 
 +</​WRAP>​
  
  
Строка 31: Строка 38:
 Tcalc = ((log(Bt$Ti_pfu) - A - C*(Bt$X_Mg^3))/​B)^0.333333;​ Tcalc = ((log(Bt$Ti_pfu) - A - C*(Bt$X_Mg^3))/​B)^0.333333;​
    
-return (data.frame(Name=Bt$Name, ​P_seq=P, T_calc_Bt_Putirka=Tcalc));+return (data.frame(Name=Bt$Name, ​T_calc_Bt_Henry_Guidotti_Thomson=Tcalc));
 } }
    
  • sensors/t/bt_henry_guidotti_thomson.1444379858.txt.gz
  • Последние изменения: 2018/11/12 15:08
  • (внешнее изменение)