====== Opx-Cpx: Mercier, 1984 ====== ONLY FOR LHERZOLITES AND HARZBURGITES, EQ.5 (discarding the questionable data points below/at 5 kbar) === Details === This sensor from [[:about_tpf|TPF]] collection ^ Article | | ^ Callibration | 51 reversed experimental data in the CMS system, plus additional data in the CMAS system and for some selected natural samples | ^ Precision | | ^ Ranges | 5-30 kbar, 800-1400 °C | ^ Renew sensors | | * заголовок * краткое описание * статья * ссылка * карточка * подробное описание * код * тест === Source === source("utilities_tpf.r"); sensors.p.opx_cpx_mercier_1984_b <- function(Opx, Cpx, usePFU=FALSE, ...){ row_names = paste0(Cpx$Name,"-", Opx$Name); if(!usePFU) { Opx <- tpf.recalc_minaral("OPX",Opx); Cpx <- tpf.recalc_minaral("CPX",Cpx); } CO <- Opx$Ca_pfu; NO <- Opx$Na_pfu; CC <- Cpx$Ca_pfu; NC <- Cpx$Na_pfu; CAOP <- CO / ((1 - NO) * (1 - NC)); CACP <- CC / ((1 - NO) * (1 - NC)); KF <- CAOP / (1 - CACP); P <- 10.73 / (KF + 0.028) - 16.5; return(data.frame(Name=row_names,P_calc=P)); } sensors.p.opx_cpx_mercier_1984_b.args <- function(){ ars <- list(); ars$minerals <- c("Opx", "Cpx"); ars$ranges <- c(); return(ars); } #sensors.p.opx_cpx_mercier_1984_b.test <- function(){ # #} {{tag> tpf Cpx Opx AP_igroup fixed}}