This sensor from TPF collection
| Article | |
|---|---|
| Collibration | |
| Presition | |
| Ranges | |
| Renew sensors |
source("utilities_tpf.r");
sensors.f.ol_fe_qtz_fonarev_1987 <- function(Ol, Fe, Qtz, Temp, P, ...){
T <- Temp;
Ol <- tpf.recalc_minaral("OL",Ol);
X <- (Ol$Fe_p2_pfu + Ol$Fe_p3_pfu) / (Ol$Fe_p2_pfu + Ol$Fe_p3_pfu + Ol$Mg_pfu + Ol$Ca_pfu + Ol$Mn_pfu + Ol$Al_c6_pfu);
Y <- - 32.544 + 0.038462 * (T + 273.15);
if (P>Y) {
TT <- 1000 / (T + 273.15);
FO2 <- 8.7391 + 2 * log(X) - 0.33 * ((1 - X)^2 + 91.7244) * TT + 1.06 * ((1 - X)^2) * TT^2 - 0.4 * P * TT / 1000;
LGFO2 <- FO2;
}
if (P<Y) {
TT <- 1000 / (T + 273.15);
LgFO2 <- 8.8467 + 2 * log(X) - 0.33 * ((1 - X)^2 + 92.0004) * TT + 1.06 * ((1 - X)^2) * TT^2 - 3.2 * P * TT / 1000;
}
return(data.frame(Name=paste0(Ol$Name),Temp=Temp,P=P,LGFO2_calc=LGFO2));
}
sensors.f.ol_fe_qtz_fonarev_1987.args <- function(){
ars <- list();
ars$minerals <- c("Ol", "Fe", "Qtz");
ars$ranges <- c("Temp", "P");
return(ars);
}
#sensors.f.ol_fe_qtz_fonarev_1987.test <- function(){
#
#}