This sensor from TPF collection
| Article | |
|---|---|
| Collibration | |
| Precision | |
| Ranges | |
| Renew sensors |
source("utilities_tpf.r");
sensors.t.grt_cpx_powell_1985_b <- function(Grt, Cpx, P, ...){
Grt <- tpf.recalc_minaral("GRT",Grt);
Cpx <- tpf.recalc_minaral("CPX",Cpx);
X <- (Grt$Fe_p2_pfu + Grt$Fe_p3_pfu) / Grt$Mg_pfu;
Y <- (Cpx$Fe_p2_pfu + Cpx$Fe_p3_pfu) / Cpx$Mg_pfu;
Z <- Grt$Ca_pfu / (Grt$Ca_pfu + Grt$Mg_pfu + Grt$Fe_p2_pfu + Grt$Fe_p3_pfu);
T <- (2790 + 10 * P + 3140 * Z) / (1.735 + log(X / Y)) - 273.15;
warning(" IN GRT X(CA)=CA/(CA+MG+FE) - (FONAREV ET AL.,1989)");
return(data.frame(Name=paste0(Cpx$Name,"-", Grt$Name),P=P,T_calc=T));
}
sensors.t.grt_cpx_powell_1985_b.args <- function(){
ars <- list();
ars$minerals <- c("Grt", "Cpx");
ars$ranges <- c("P");
return(ars);
}
#sensors.t.grt_cpx_powell_1985_b.test <- function(){
#
#}