Править страницу Ссылки сюда Opx-Cpx: Bertrand, Mercier, 1985 This geothermometer is directly applicable to the natural system as illustrated by the remarkable agreement between the experimental conditions and the calculated temperatures for reequilibration experiments on natural systems. Details Source Philippe Bertrand, Jean-Claude C. Mercier The mutual solubility of coexisting ortho- and clinopyroxene: toward an absolute geothermometer for the natural system?, 1985 [ref] Callibration 36 points from different sources Accuracy 2% Ranges 810-1500°C and 0.0-10.0 GPa Renew sensors Использовать Проверить заголовок краткое описание статья ссылка карточка подробное описание код тест Code source("utilities_tpf.r"); sensors.t.opx_cpx_bertrand_mercier <- function(Opx, Cpx, P, usePFU=FALSE, ...){ row_names <- paste0(Opx$Name,"-",Cpx$Name); if(!usePFU) { Opx <- tpf.recalc_minaral("OPX",Opx); Cpx <- tpf.recalc_minaral("CPX",Cpx); } X = Opx$Na_pfu; Y = Opx$Ca_pfu; Z = Cpx$Na_pfu; F = Cpx$Ca_pfu; K = Cpx$Fe_pfu /(Cpx$Fe_pfu + Cpx$Mg_pfu); A = 36273+399*P/10; C = 1-Y/(1-X); B = F/(1-Z)+(-0.77+0.001*T)*K; L = log((1-B)/C); T = A/(19.31-8.314*L-12.15*B**2); T = T-273; return(data.frame(Name=row_names,P=P, T_calc=T)); } sensors.t.opx_cpx_bertrand_mercier.args <- function(){ ars <- list(); ars$minerals <- c("Opx", "Cpx"); ars$ranges <- c("P"); return(ars); } #sensors.t.opx_cpx_bertrand_mercier.test <- function(){ # #} AP igroup, fixed sensors/t/opx_cpx_bertrand_mercier.txt Последние изменения: 2018/11/12 15:07(внешнее изменение) Войти