Grt-Crd-Sil-Qtz: Thompson, 1984

Details

This sensor from TPF collection

Article
Collibration
Precision
Ranges
Renew sensors

Использовать Проверить

  • заголовок
  • краткое описание
  • статья
  • ссылка
  • карточка
  • подробное описание
  • код
  • тест

Source

source("utilities_tpf.r");

sensors.p.grt_crd_sil_qtz_thompson_1984 <- function(Grt, Crd, Temp, ...){
    Name <- paste0(Crd$Name,"-", Grt$Name);
    T <- Temp;
    Grt <- tpf.recalc_minaral("GRT",Grt);
    Crd <- tpf.recalc_minaral("CRD",Crd);

    X <- (Crd$Fe_p2_pfu + Crd$Fe_p3_pfu) / (Crd$Fe_p2_pfu + Crd$Fe_p3_pfu + Crd$Mg_pfu);
    Y <- (Grt$Fe_p2_pfu + Grt$Fe_p3_pfu) / (Grt$Fe_p2_pfu + Grt$Fe_p3_pfu + Grt$Mg_pfu);
    TT <- T + 273;
    K <- log(X / Y);
    P <- (1 + (13994.5 - 7.601 * TT - 6 * TT * K)) / 1.9558 / 1000;
    return(data.frame(Name=Name,Temp=Temp,P_calc=P));
}

sensors.p.grt_crd_sil_qtz_thompson_1984.args <- function(){
    ars <- list();
    ars$minerals <- c("Grt", "Crd");
    ars$ranges <- c("Temp");
    return(ars);
}

#sensors.p.grt_crd_sil_qtz_thompson_1984.test <- function(){
#
#}
, ,
  • sensors/p/grt_crd_sil_qtz_thompson_1984.txt
  • Последние изменения: 2020/02/19 13:25
  • — f0ma